It is a fire door show something to recognize when you see it? Most people have seen this door in many places, but may not be aware that these doors provide an essential function to keep people away from the sudden spread of fire inside a building. Propagation rates can sometimes be faster, depending on the materials used for the structure. If they are made from engineered wood and are not thick, and is easy to achieve combustion. Leave doors the right to keep the door fire will ensure that they will operate according to their destination in a fire accident.

These doors fire their specific assessments are given. Only authorized persons or companies install and certify this type of door assemblies.

There are key to ensure that the doors are installed correctly points:

fire door frames must be installed according to the tested prototypes requirements. Any material that is not fireproof, will not take place through the door. Once inspectors find that some components such as frames not qualify as a fire stop material, replacing all the correct door is recommended.

The space between the door and the frame of the head should not exceed 3 mm. This also includes amounts. For the finished floor level, the clearance from the bottom of the door in the floor must not exceed 10 mm. There may be situations where it would be impractical to observe the measure, but it would be prudent to postpone the expert for the maintenance of the fire door before proceeding with the installation.

In addition, each type of material that can be found on the door is closed and locked as it should have to be approved as fire resistant. There are representatives in your area who can testify to the quality of the material so that eventually the fire, blocking flames, heat and smoke produced is actually possible.

All edges may be cut with a maximum of 6 mm. However, if more needed trimming, we recommend a door custom size you can ask a certified supplier.

Doors must be hung properly for those with gusset plates can be made to fit the hinges, door closers and locks. Tile upper hinge has a prepaid label indicating that it is a top hinge. The label will also sport the side of the door.

There tapping screws that can fix the narrowest and hinges against the door leaf. Or use a self tapping screw 35 mm x 4.91mm 10 gauge for him. Create a pilot 4mm screw for fixing hole. In addition, the handles of the buttons must be a minimum of 127 mm fixed return. Handles must also have approved locks.

Since the failure to follow the requirements will result in a default rating to the door, then the certificate can not be issued by the door, invalidating the warranty. Therefore, to avoid these problems to the surface, it would be best to comply with the regulations for fire doors.